Showing results: 1531 - 1545 of 2477 items found.
-
40-614-002 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-001 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-019 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-003 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-007 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40-614-016 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
40465 -
Pulse Instruments
Two channels of 10MHz drivers, that can be operated as standard Two-Level Drivers or operated as two channels of Tri-Level Drivers. In the Two-Level mode, the input to each driver channel requires one channel of TTL level timing. Tri-and four level modes require a second clock input. In the Tri-Level Mode, the output from lowest rail to high rail can be 18.5V. Like the 40460 the rise and fall time as well as the high and low voltage levels of each channel is programmable.
-
BLC Series -
Behlman Electronics Inc.
The BLC Series delivers all the quality features our customers have come to expect from Behlman; clean sine wave output with excellent line and load regulation, high efficiency and low harmonic distortion. A multi-pulse input transformer offers low-input harmonic distortion and high power factor as required by European standards. Unique protection circuitry provides for over-temperature protection; short-circuit protection and voltage fold-back during overloads to maintain undistorted waveforms.
-
Octane Elect EDS System -
EDAX
The Octane Elect EDS System is an enhanced Energy Dispersive Spectroscopy (EDS) platform with the latest advancements in Silicon Drift Detector (SDD) technology and high speed electronics. Tailored for users who demand higher performance and functionality than the options available in entry-level systems, the Octane Elect EDS System provides excellent resolution and high throughput at an optimal value with a remarkable low energy sensitivity for light element detection and low voltage (kV) microanalysis.
-
Signals & Systems India Private Limited
Large Display indicator measures and displays frequency from the input like supply voltage, 4-20mA and data received from other equipment. It meets high accuracy of 0.1% to measure Frequency. The large display is for clear visibility of the frequency reading from long distance. It is equipped with high bright red color 7segment displays. These are commonly used in Power plants, Substations, Manufacturing units and Field environments to provide direct frequency measurements of various devices.
-
ST-1504 -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Measures insulation(MΩ), continuity(Ω) and AC voltage.● Instant operation is possible with a push button, convenient timer is provided with automatic power off after three to five minutes to save the battery power.● LED (red) indication when testing insulation and continuity.● Use of a high efficiency and accurate DC-DC converter.● Most suitable for insulation resistance measurement of electrical household appliances, power line distribution and installation.
-
ST-1503 -
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Measures insulation(MΩ), continuity(Ω) and AC voltage.● Instant operation is possible with a push button, convenient timer is provided with automatic power off after three to five minutes to save the battery power.● LED (red) indication when testing insulation and continuity.● Use of a high efficiency and accurate DC-DC converter.● Most suitable for insulation resistance measurement of electrical household appliances, power line distribution and installation.
-
40-614-010 -
Pickering Interfaces Ltd.
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
CAEN S.p.A.
- From 12 to 48 independently controllable High Voltage channels- 0 ÷ 1.5 kV (A1538D) and 0 ÷ 1/1.3/1.4 kV output voltage (A1515B)- Maximum Current 10 mA, 0.1 or 1/0.1, 3/0.3 mA (dual range boards)- Radiall Multipin, SHV or DB37 connectors- Available with either positive or negative polarity (A1538D and A7038)- Up to 2 nA / 100 pA current set / monitor resolution- Up to 20 mV / 2 mV voltage set / monitor resolution- Very low ripple, down to < 5 mVpp- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Full Floating (A1515B only)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down - TRIP parameter- Current generator operation in overcurrent condition- Specific design for GEM and Vertex detector and dedicatedaccessories (A1515B boards only)
-
SS71XX series -
Sanshine Electronis Co., Ltd.
High voltage withstand and insulation tester (HI-POT tester) is used for testing insulation grade and withstanding voltage capability of electrical equipment, transformers, motor, relays, cables, electronic components, electronic applications, inductors, ignition coils, insulation wires, insulation tapes, valve coils, reactors, contactors, etc.